{"product_id":"ioptron-8417-15","title":"iOptron AC Adaptor, 1.5A","description":"\u003cul class=\"DAV-feature-list\"\u003e\n\u003cli\u003e1.5A Current Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- more --\u003e\n\u003cul class=\"tabs\"\u003e\n\u003cli class=\"active\"\u003eDescription\u003c\/li\u003e\n\u003cli\u003eFAQ\u003c\/li\u003e\n\u003cli\u003eSpecifications\u003c\/li\u003e\n\u003cli\u003eIn the Box\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul class=\"tabs-content\"\u003e\n\u003cli class=\"active\"\u003e\n\u003cdiv\u003e\n  \u003cdiv class=\"DAV-bg-light\"\u003e\n    \u003cdiv class=\"DAV-section-center\"\u003e\n      \u003ch2\u003eAC Adaptor, 1.5A\u003c\/h2\u003e\n      \u003cp\u003eThis AC Adapter provides a regulated 1.5A current, designed to safely power specific astronomy mounts and accessories with modest energy requirements. It serves as a fundamental component for running equipment from a standard wall outlet, eliminating the need for portable battery packs during backyard observing sessions.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003cdiv class=\"DAV-bg-light\"\u003e\n    \u003cdiv class=\"DAV-section\"\u003e\n      \u003ch3\u003eReliable 1.5A Power for Astronomy Accessories\u003c\/h3\u003e\n      \u003cp\u003eA stable power source is critical for the proper function of electronic astronomy equipment. This adapter is rated for a 1.5A (ampere) load, making it suitable for many popular star trackers, smaller GoTo mounts running tracking motors without heavy slewing, or single, low-draw accessories like a basic dew heater strip. Using an adapter with the correct amperage prevents voltage drops that can cause tracking errors or electronic resets. Before use, always confirm the power requirements (voltage and amperage) of your specific device to ensure compatibility.\u003c\/p\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n  \u003cdiv class=\"DAV-accordion\"\u003e\n    \u003ch3 class=\"DAV-accordion-Q\"\u003eWhat is this 1.5A AC Adapter typically used for in astronomy?\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion-A\"\u003e\n    \u003cp\u003eA \u003cstrong\u003e1.5A adapter\u003c\/strong\u003e is generally sufficient for powering lower-demand devices. This includes most portable star trackers, the tracking motors on smaller equatorial mounts (when not slewing at high speed), and some standalone accessories like electronic filter wheels or a single, small dew heater strip.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion\"\u003e\n    \u003ch3 class=\"DAV-accordion-Q\"\u003eIs 1.5A sufficient to power a GoTo mount like a Celestron NexStar 6SE?\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion-A\"\u003e\n    \u003cp\u003eIt depends on the operation. While 1.5A might be enough to run the tracking motors on a NexStar 6SE for visual observation, it may be insufficient for high-speed GoTo slewing, which can cause a current spike. Many mid-sized GoTo mounts recommend a power supply of 2.5A or more to handle peak loads without issue. Always check your mount's specific power requirements in its manual.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion\"\u003e\n    \u003ch3 class=\"DAV-accordion-Q\"\u003eWhen would I need a power supply with more than 1.5A?\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion-A\"\u003e\n    \u003cp\u003eYou will need a higher amperage power supply if you are running multiple devices or a single device with a high power draw. Common scenarios include:\u003c\/p\u003e\n    \u003cul\u003e\n        \u003cli\u003e\n\u003cstrong\u003eLarge GoTo Mounts:\u003c\/strong\u003e Mounts like the Celestron CGX or iOptron CEM70 require 3A to 5A or more.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCooled CMOS\/CCD Cameras:\u003c\/strong\u003e The thermoelectric cooler (TEC) on an astro-camera is power-intensive and typically requires at least 3A on its own.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMultiple Dew Heaters:\u003c\/strong\u003e Running a dew controller for several heater strips will quickly exceed a 1.5A capacity.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion\"\u003e\n    \u003ch3 class=\"DAV-accordion-Q\"\u003eCan I use this 1.5A adapter to power a cooled astronomy camera?\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion-A\"\u003e\n    \u003cp\u003eNo. Cooled astronomy cameras, such as those from ZWO or QHY, require significantly more current to run their thermoelectric cooling (TEC) systems, often in the range of 3A to 5A. A 1.5A adapter is insufficient and will not allow the camera's cooler to function correctly.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion\"\u003e\n    \u003ch3 class=\"DAV-accordion-Q\"\u003eWhat are the risks of using an underpowered adapter for my telescope?\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion-A\"\u003e\n    \u003cp\u003eUsing an underpowered adapter can lead to intermittent equipment failure and poor results. When a device like a mount tries to draw more current than the adapter can supply, the voltage drops. This can cause the mount's computer to reset, ruin a long exposure by causing a tracking error, or even lead to the adapter overheating and failing.\u003c\/p\u003e\n  \u003c\/div\u003e\n    \u003cdiv class=\"DAV-accordion\"\u003e\n    \u003ch3 class=\"DAV-accordion-Q\"\u003eWill this 1.5A adapter be enough to run a Sky-Watcher Star Adventurer and a single dew heater?\u003c\/h3\u003e\n  \u003c\/div\u003e\n  \u003cdiv class=\"DAV-accordion-A\"\u003e\n    \u003cp\u003ePossibly, but it would be at the limit. A Sky-Watcher Star Adventurer has a very low power draw for tracking. However, even a small dew heater strip can draw close to 1A on its own. Combining the two could exceed the 1.5A rating, especially if the dew heater is set to a high level. It is safer to use a power supply with a higher rating (e.g., 2.5A or more) if you plan to run accessories alongside your mount.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n  \u003ctable class=\"DAV-specifications\"\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e1.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n  \u003cul class=\"DAV-grid\"\u003e\n  \u003c\/ul\u003e\n\u003c\/li\u003e\n\n\u003cli\u003e\n\u003ca href=\"https:\/\/davidastro.com\/pages\/warranty-information\" rel=\"noopener\" target=\"_blank\"\u003eStandard Warranty Information\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"iOptron","offers":[{"title":"Default Title","offer_id":52917310980381,"sku":"IOP-8417-15","price":26.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0753\/5280\/1565\/files\/iOptron-AC-Adaptor-1-5A-1_d188b498-3447-4e2f-bcac-8678d94c87a0.jpg?v=1789142526","url":"https:\/\/davidastro.com\/en-us\/products\/ioptron-8417-15","provider":"David Astro","version":"1.0","type":"link"}