Shelyak Adapter cord for the SPOX module
- Official Shelyak accessory cable
- Connects the SPOX remote control module
- Enables control of calibration lamps
- Compatible with Alpy 600 and LISA spectrographs
This adapter cord is the essential link for the Shelyak SPOX remote calibration module. It provides the specific connection required to control the tungsten (flat field) and Neon/Argon (wavelength calibration) lamps on Shelyak's Alpy 600 and LISA spectrographs. This cable ensures a reliable connection for automated or manual calibration sequences managed by the SPOX controller.
Designed as a direct complement or replacement part, this adapter cord facilitates the connection between your spectrograph's calibration unit and the SPOX control box. Without the correct cable, remote operation is impossible. This genuine Shelyak part guarantees proper fit and electronic compatibility, protecting your sensitive instruments from incorrect connections.
This cord connects the end of the SPOX main cable (0.8 m or 5 m) to the calibration module of an Alpy 600 or LISA. Its purpose is to carry power and control signals to the lamps of the calibration module (Tungsten for flats, Neon/Argon for wavelength calibration).
This adapter cord is designed for use with the SPOX module and the Alpy 600 and LISA spectrographs. The Lhires III connects to the SPOX main cable directly and does not need it.
Yes, for the Alpy 600 and LISA: if you are using the SPOX module to remotely control their calibration lamps, this cord (or the one supplied with your SPOX order) must be plugged into the end of the SPOX main cable. The Lhires III does not need it.
It is strongly advised to only use the official Shelyak Instruments adapter cord. Using a generic or third-party cable may result in an improper connection, unstable operation, or potential damage to the sensitive electronics in the SPOX module or your spectrograph.
No. On a Lhires III, the SPOX main cable plugs directly into the 4-pin socket on the side of the spectrograph, so this adapter cord is not needed. It is used only with the Alpy 600 and LISA.
No, this cord facilitates the connection from the SPOX module to the spectrograph's lamps. The SPOX module itself needs a separate 12V DC power supply delivering at least 1 A, plugged into its 5.5 mm DC socket.
| Kind | SPOX adapter cable for Alpy 600 and LISA |
| Connector | Plugs into the end of the SPOX 4-pin main cable; black (power), yellow (calibration lamp) and white (flat lamp) connectors to the Alpy calibration module; on LISA the black connector is not used |
Complement cable SPOX
× 1