Shelyak Grating module for the Lhires III - 1800 l/mm
- Grating Ruling: 1800 lines/mm
- Compatibility: Shelyak Lhires III Spectroscope
- Function: Alternative module to change native resolution
- Use Case: Wider spectral coverage at lower resolution
This interchangeable grating module provides a ruling of 1800 lines/mm, specifically designed to alter the native high-resolution capabilities of the Shelyak Lhires III spectroscope. It allows you to trade the maximum resolving power of the standard 2400 l/mm grating for a somewhat wider spectral window in a single exposure.
In spectroscopy, there is a fundamental trade-off between resolution and spectral coverage. This 1800 l/mm grating module for the Lhires III is engineered for situations where capturing a broader range of wavelengths is more critical than achieving the highest possible resolution. By decreasing the line density from the standard 2400 l/mm, this grating disperses light less, fitting more of the spectrum onto your camera sensor.
This makes it useful when you want a wider window around a chosen line than the 2400 l/mm gives. With limiting magnitudes of 5.0 (2400 l/mm) and 6.8 (1200 l/mm) in Shelyak's table for a 200 mm telescope and a 1 h exposure, it is suited to bright stars and bright novae.
The Lhires III spectroscope ships with a 2400 l/mm grating, which is optimized for high-resolution studies of specific, narrow spectral regions. This alternate 1800 l/mm module extends the instrument's capabilities, turning it into a more adaptable research tool.
You would choose the 1800 l/mm grating when your primary goal is to capture a wider range of wavelengths in a single exposure. The standard 2400 l/mm grating offers higher resolution but sees a smaller piece of the spectrum. The 1800 l/mm module suits bright stars and bright novae when a wider window around a line matters more than the finest detail.
The 1800 l/mm grating suits bright targets where a wider window around one line helps. Good examples include:
Yes, this is a fully compatible, interchangeable module designed by Shelyak specifically for the Lhires III spectroscope. It is intended to be swapped with the standard 2400 l/mm grating to change the instrument's optical characteristics based on your observing target.
No. Shelyak's Lhires III figures give a field of about 8.5 nm per image with the standard 2400 l/mm grating and about 25 nm with the 1200 l/mm grating, so the 1800 l/mm grating sits between the two. The Balmer lines of Vega run from H-gamma (434 nm) to H-alpha (656 nm), so each line needs its own exposure.
By dispersing starlight over a smaller area (lower dispersion), the 1800 l/mm grating can produce a brighter continuum in the resulting spectrum compared to the 2400 l/mm grating, assuming equal exposure time and conditions. This can be advantageous for obtaining a better signal-to-noise ratio on the overall spectrum of fainter objects.
Yes, absolutely. Any time you change the diffraction grating in a spectroscope, you change the instrument's dispersion (how many angstroms per pixel). You will need to perform a new spectral calibration using a calibration lamp to accurately measure wavelengths with the 1800 l/mm grating installed.
| Fits (mount / scope) | Shelyak Lhires III |
| Fits Spectrograph | Shelyak Lhires III |