Skip to content

Language

Country

Shelyak Alpy 600 Spectroscope

by Shelyak
SKU SHK-PF0035
Original price $978.00 USD - Original price $978.00 USD
Original price
$978.00 USD
$978.00 USD - $978.00 USD
Current price $978.00 USD
Price Match Policy!
  • Resolution Power of R~600 with the 25µm slit
  • Spectral Resolution of approximately 1nm
  • Fast F/4 optical design for high light throughput
  • Multi-position slit wheel with 25µm, 50µm, 100µm, and 300µm options
  • Covers a wide 370-750 nm wavelength range
  • Compact 65mm body weighing only 200g
1 in stock
FREE Shipping in CONUS
  • Description
  • FAQ
  • Specifications
  • In the Box
  • Downloads
  • Warranty
  • Shelyak Alpy 600 Spectroscope

    The Shelyak Alpy 600 Spectroscope is a complete scientific instrument that packs a resolving power of R~600 into a compact body just 65mm long and weighing only 200g. Its fast F/4 optical design and multi-position slit wheel, featuring a 25µm slit for ~1nm spectral resolution, provide a versatile platform for astrophysical discovery. With a flexible mechanical backfocus range of 10.5mm to 21mm, the Alpy 600 integrates easily into existing imaging trains to measure the temperature of a star, define its spectral class, or track the expansion of a nova.

    An R~600 Spectroscope for Discovery and Science

    The Alpy 600 is an entry into slit-based spectroscopy. It enables you to move beyond simple imaging and begin analyzing the physical properties of celestial objects. This instrument is for the dedicated amateur astronomer ready to produce high-quality scientific data on stars, nebulae, galaxies, comets, and planets.

    Unlike simpler slitless gratings that blend the light of your target with the background sky, the Alpy 600's slit isolates a specific object. This fundamental design choice produces clean, high-contrast spectra, making your data robust and independent of seeing conditions or minor tracking errors. It is the key to accurate wavelength calibration and the study of extended objects, turning your observations into verifiable measurements suitable for pro-am collaboration.

    The 600 lines/mm Grism Optical System

    At the heart of the Alpy 600 is a dispersing element called a grism. This component is a hybrid of a prism and a diffraction grating, combining the light-dispersing power of a 600 lines/mm grating with the on-axis transmission of a prism. This clever design spreads the incoming light into a detailed spectrum while keeping the optical path straight, resulting in a compact and rigid instrument.

    The on-axis design eliminates the significant beam deviation that occurs with a standalone grating. The result is an on-axis instrument. The Alpy 600 is robust, insensitive to temperature variations and requires few adjustments.

    R~600 Performance Across the 370-750 nm Spectrum

    The Alpy 600 delivers a resolving power (R) of approximately 600 when using the 25µm slit. This level of resolution allows you to distinguish spectral features separated by about 1nm, which is sufficient to identify key absorption and emission lines across the visible spectrum. The instrument's effective wavelength range spans from 370 nm in the near-ultraviolet to 750 nm in the near-infrared.

    • Identify Spectral Classes: The R~600 resolution lets you classify stars based on their spectral features, from hot O- and B-type stars with strong helium lines to cool M-type stars with prominent molecular bands.
    • Observe Emission Lines: You can clearly resolve the H-alpha emission in Be stars, track the evolution of novae, and identify the characteristic lines of planetary nebulae.
    • Follow Variable Stars: You can watch variable stars evolve from day to day and compare different spectral types.

    The Multi-Position Slit Wheel from 25µm to 3mm

    The slit is a critical component that defines the resolution and contrast of your spectrum. The Alpy 600 includes a multi-position wheel with a variety of apertures to match different targets and observing conditions, with a slit length of 3mm (except the 25µm hole).

    • 25µm, 50µm, 100µm, 300µm Slits: This range allows you to make the critical trade-off between resolution and light throughput. The 25µm slit is the standard slit and gives the R~600 resolution. Use the 300µm slit when you have no guiding module but want to remove most of the sky background, or to collect all the light of a star whose image is larger than 25µm.
    • 25µm Hole: The spectrum always falls at the same position in the image, which reproduces on the bench what you will see with stars.
    • 3mm Hole: This large aperture effectively puts the spectroscope into a "slitless" mode. This is for point-like stars: you see a larger star field and can easily find the star you are looking for. Keeping the 3mm hole in place, rather than removing the slit, limits optical aberrations at the field edges.

    Optimized for F/4 and Apertures from 80mm

    The Alpy 600 features a fast F/4 optical design, ensuring maximum light throughput and high efficiency. While it performs optimally at F/5, it is designed to work well with telescopes from F/4 to F/10. This versatility means it can be paired with a wide range of instruments, from fast refractors and Newtonians to Schmidt-Cassegrains, with or without a focal reducer.

    Its lightweight 200g body and compact 65mm x 45mm dimensions make it suitable for use on telescopes with apertures as small as 80mm, mounted on modest equatorial mounts. This accessibility allows you to begin capturing spectra of bright to moderately faint objects without needing a massive observatory-class setup. The spectroscope performs best with telescopes up to 400mm in aperture.

    Mechanical Interfaces: 10.5-21mm Backfocus and Standard M42 Threads

    Integrating the Alpy 600 into your imaging train is straightforward thanks to its use of standard mechanical interfaces. The camera-side connection is a standard T-mount thread (M42x0.75mm).

    The camera's mechanical backfocus can be anywhere in a 10.5mm to 21mm range. On the telescope side, the Alpy 600 comes equipped with a 1.25" nosepiece, which screws into the M42x0.75 thread of the external body; the same thread is used on both ends of that body. This allows you to easily swap the 1.25" nosepiece for a standard 2" adapter if needed.

    Camera Requirements: Sensor Size and Backfocus Considerations

    To capture the full 370-750 nm spectral range of the Alpy 600, your camera's sensor should have a minimum length of 8.5mm along the dispersion axis. Any camera with a sensor longer than 14mm and a mechanical backfocus between 10 and 20mm will do.

    A DSLR can be used, but its standard backfocus of ~55mm is well beyond the Alpy 600's native 10.5-21mm range. To accommodate this, the optional Alpy DSLR Barlow Adapter is required to extend the spectroscope's focal point to reach the DSLR sensor. The ZWO ASI533MM Pro camera is recommended for spectra acquisition with the Alpy 600.

    Modularity: The Optional Guiding and Calibration System

    The Alpy 600 is a complete spectroscope on its own, and it can be extended with two optional modules.

    • Guiding Module: This essential upgrade provides a view of the field around the slit. It allows you to see your target star and accurately place it onto the narrow slit, then use an autoguiding camera to keep it there for long exposures. This is the key to comfort, efficiency, and data quality.
    • Calibration Module: For data to be scientifically valuable, it must be calibrated. This module provides a built-in Argon-Neon lamp for precise wavelength calibration and a halogen lamp for flat-fielding. It removes guesswork and ensures your measurements are accurate and repeatable.

    With the calibration module and the guiding module fitted, the total backfocus is 64mm.

    From Acquisition to Analysis with Demetra Software

    Shelyak provides the Demetra software, available as a free download, to manage the entire spectroscopy workflow. Designed specifically for the Alpy 600, Demetra guides you from initial setup and image acquisition to fully processed and calibrated scientific data.

    Demetra integrates camera control (via ASCOM), session management, and a guided data reduction pipeline. It prompts you for necessary calibration frames (such as darks, flats and reference lamp spectra) and uses a color-coded system to show the completeness of your data set. The processing is fully automated yet transparent, allowing you to follow each step from raw image to final, scientifically-valid spectral profile. This all-in-one solution streamlines the complex process of spectroscopy, letting you focus on your targets.

    Pro-Am Projects with the Alpy 600

    The data quality produced by the Alpy 600 is sufficient for contributing to a wide range of scientific and pro-am collaboration projects. Its R~600 resolution enables meaningful analysis that goes far beyond pretty pictures.

    • Emission-Line Stars: Observe absorption and emission lines and follow how they change over time in active stars.
    • Novae: The Alpy 600's uses include measuring the expansion velocity of a nova.
    • Variable Star Spectroscopy: Observe the spectral changes in variable stars as they cycle through their periods of brightness, revealing the physical processes driving their variability.
    • Comet and Planet Analysis: Comets and planets are among its targets; with the slit you can work on extended objects such as planets.

    A Compact 200g Instrument and First Light

    The Alpy 600 is engineered to be compact, robust, and easy to use. The main body is just 65mm long with a 45mm diameter, and the entire unit weighs a mere 200g. This compactness makes it compatible with small telescopes from 80mm diameter on modest mounts.

    Getting started is a straightforward process. The recommended learning path is to begin with daylight observations of the solar spectrum or household lamps to familiarize yourself with focusing, slit selection, and the data reduction process in Demetra. From there, you can move to the telescope for visual observations of bright stars in slitless mode (using the 3mm hole), before progressing to capturing your first scientific, slit-based stellar spectra.

  • What kind of scientific projects can I do with the Shelyak Alpy 600?

    The Alpy 600's R~600 resolution opens the door to many pro-am projects. You can classify stars by their spectral type (O, B, A, F, G, K, M), measure the expansion velocity of a nova, or monitor the changing spectra of variable stars and comets.

    How do I choose the right slit size (25µm, 50µm, 100µm, 300µm) for my target with the Alpy 600?

    The choice is a trade-off between resolution and light throughput. For the highest detail on bright stars to resolve fine spectral features, use the narrowest slits (25µm or 50µm). For faint, extended objects like nebulae or galaxies where collecting photons is the priority, use the wider slits (100µm or 300µm) at the cost of lower resolution.

    Can I use my DSLR camera with the Shelyak Alpy 600?

    Yes, but with an adapter. A DSLR with a standard T-ring has a backfocus of about 55mm, which is too long for the Alpy 600's native 10.5-21mm range. You will need the optional Alpy DSLR camera barlow adapter to achieve focus.

    What is the advantage of the Alpy 600's R~600 resolution for observing Be stars like Gamma Cassiopeiae?

    An R~600 resolution suits Be stars like Gamma Cassiopeiae (Navi). It allows you to clearly resolve the prominent Hydrogen-alpha emission line at 656.3 nm that characterizes these stars. This feature appears as a sharp spike "filling in" the normal absorption line. With the Alpy 600, you can monitor the strength and shape of this emission line over time to track activity in the star's circumstellar disk.

    How does the Alpy 600 perform on a bright planet like Jupiter with an 8" SCT?

    The slit lets the Alpy 600 work on extended objects such as planets, for example with an 8" f/10 SCT. You can orient the slit across Jupiter's disk to see the absorption bands of methane and ammonia in its atmosphere. By comparing the spectra of the dark belts and bright zones, you can look for differences between them.

    Do I need the optional guiding and calibration modules for the Shelyak Alpy 600?

    While not required to start, the optional modules significantly improve the scientific workflow. The guiding module lets you see the field of view to accurately place and keep your target on the narrow slit, which is very difficult otherwise. The calibration module provides a reference lamp (Argon-Neon), which is essential for precise wavelength calibration, turning your data from a picture into a scientific measurement.

    What is the difference between the Alpy 600's slit mode and a simple slitless grating?

    A slitless grating is simpler but merges your target's spectrum with the sky background and any nearby stars. The Alpy 600's slit physically blocks out this unwanted light, producing a clean, high-contrast spectrum. This isolation is essential for accurate calibration, observing faint or extended objects, and producing reliable data regardless of seeing or tracking quality.

    What is a "grism" and why does the Alpy 600 use one?

    A grism is a combination of a diffraction griting and a prism. The grating spreads the light into a spectrum, while the prism corrects the angle of the light path. This allows the Alpy 600 to have a straight-through, "on-axis" optical design, making the instrument much more compact, rigid, and easier to mount than spectrographs with more complex folded light paths.

    What camera sensor size is best for the Alpy 600?

    To capture the full 370-750 nm wavelength range, a sensor with a length of at least 8.5mm is required. A sensor longer than 14mm will do. The camera's mechanical backfocus must be within the 10.5mm to 21mm range.

    What software is needed to process data from the Alpy 600?

    Shelyak provides its own free software, Demetra, which is designed to handle the entire workflow from image acquisition to fully calibrated spectra. It is an all-in-one solution for controlling your camera (via ASCOM), managing observing sessions, and performing the necessary data reduction steps. Other tools like ISIS and AudeLA can also be used.

    How is the Alpy 600 focused and aligned?

    There are two focus adjustments. First, the spectroscope itself is focused to the camera by threading the main body in or out of the camera adapter to make the spectral lines sharp. Second, you focus the telescope to make the spectrum as thin (vertically) as possible. Alignment is done by rotating the Alpy 600 core inside its body to make the spectrum horizontal in your camera frame.

    Is the Alpy 600 sensitive to temperature changes during the night?

    No, the Alpy 600 is designed to be robust and insensitive to typical ambient temperature variations during an observing session. It requires few adjustments.

  • Resolution Power R ~600 (with 25µm slit)
    Spectral Resolution ~1nm (with 25µm slit)
    Aperture F/4
    Slit Options Multi-position wheel with 25µm, 50µm, 100µm, 300µm slits (5µm tolerance); 25µm hole; 3mm hole
    Slit Length 3mm
    Weight 200g
    Dimensions 65mm length, 45mm diameter
    Camera Interface T-mount thread (M42x0.75mm)
    Mechanical Backfocus 10.5mm to 21mm range
    Total Backfocus (with modules) 64mm
    Wavelength range 370-750 nm
    Telescope-side connection 1.25" nosepiece (M42x0.75 thread on external body)
    Dispersing element Grism (prism and 600 lines/mm grating)
    Telescope aperture from 80 mm; best used with telescopes up to 400 mm
    • Alpy 600 spectroscope, assembled in slit configuration

      × 1

    • Multi-position slit (25, 50, 100, 300 µm slits; 25 µm and 3 mm holes)

      × 1

    • 1.25-inch nosepiece

      × 1

    • Tool set

      × 1

  • Shelyak 1-Year Warranty