Skip to content

Language

Country

QHYCCD QHY990 Series SWIR Camera

by QHYCCD
SKU QHY-110090
Original price $14,980.00 - Original price $14,980.00
Original price
$14,980.00
$14,980.00 - $14,980.00
Current price $14,980.00
Price Match Policy!
  • Sony IMX990 InGaAs sensor for short-wave infrared (SWIR) imaging
  • Broad spectral response from 400 nm to 1700 nm
  • High 77% peak Quantum Efficiency at 1200 nm
  • Regulated air cooling achieves a ΔT of 35°C below ambient
  • 1296 x 1032 resolution with 5.0 µm pixels
  • High-speed 66 FPS readout at full resolution (8-bit and 16-bit)
  • Integrated 25mm filter holder with standard C-mount interface
Backordered
Availability Info
FREE Shipping in CONUS
Framing Simulator
Framing SimulatorInstant FOV Preview

Preview your camera's FOV

See exactly how your targets fit with the QHYCCD QHY990 Series SWIR Camera, on real sky survey data.

Launch Imaging Assistant
Vignetting Calculator

Will your imaging train vignette?

Check which filter and adapter sizes clear the sensor with the QHYCCD QHY990 Series SWIR Camera, and how much light the corners lose.

Check vignetting
  • Description
  • FAQ
  • Specifications
  • In the Box
  • Downloads
  • Warranty
  • QHYCCD QHY990 Series SWIR Camera

    The QHYCCD QHY990 Series SWIR Camera brings the advanced Sony IMX990 InGaAs sensor to scientific imaging, opening up the short-wave infrared spectrum from 400 nm to 1700 nm. Its 1296 x 1032 resolution sensor features 5.0 µm pixels and achieves a peak Quantum Efficiency of 77% at 1200 nm, and a dual-stage TEC cooler provides a cooling delta of 35°C below ambient to suppress thermal noise, while the USB 3.0 interface delivers a full-resolution frame rate of 66 FPS.

    Sony InGaAs Sensor: 400-1700 nm Imaging with 77% Peak QE

    At the heart of the QHY990 is a Sony InGaAs sensor for scientific short-wave infrared imaging. Its spectral response begins in the visible spectrum at 400 nm and extends deep into the SWIR band to 1700 nm. Its applications are SWIR astronomy imaging and photometry, daytime star observation, optical communications, laser, scientific research and optical laboratory work, as well as low-light detection and biological imaging.

    The sensor uses Cu-Cu (copper-to-copper) interconnect technology, which gives very low FPN noise and a low defect pixel ratio.

    Scientific Signal Character: 112,000e- Full Well Capacity and 12-bit ADC

    The QHY990 has a typical full well capacity of 112,000 e- per 5.0 µm pixel, which leaves room before bright areas saturate.

    The analog signal is digitized by a 12-bit ADC, which provides 4,096 levels. Typical read noise is 135 e-, measured after bias frame FPN calibration, and dark current is 64.6 e-/pixel/sec at -30°C and gain 0. The electronic global shutter ensures that every pixel begins and ends its exposure simultaneously, so it avoids rolling shutter distortion of moving subjects.

    Advanced Thermal Management: ΔT 35°C Air Cooling for Dark Current Suppression

    InGaAs sensors typically have larger dark currents than silicon-based sensors, so powerful cooling is necessary. The QHY990 uses a dual-stage TEC cooler that reaches 35°C below ambient (test temperature 20°C).

    QHYCCD measured the effect at an ambient temperature of 25°C: the QHY990's dark current was 1477.26 e-/pixel/s with the sensor at +10°C and 250.55 e-/pixel/s at -10°C, so even a 3 second exposure shows far less noise when cooled. QHYCCD applies its own cooling and sealing technology from its astronomical cameras rather than Sony's built-in sensor cooling.

    QHYCCD writes that the QHY990 Series supports both air cooling and liquid cooling, with liquid cooling reaching 45°C below ambient with normal water and 60°C to 80°C below ambient with cold liquid.

    High-Throughput Imaging: 66 FPS at Full Resolution via USB 3.0

    The QHY990 reaches a maximum frame rate of 66 FPS at its full 1296 x 1032 resolution. The rate is the same at 8-bit and 16-bit output. A 128MB DDR2 memory buffer holds frames during transfer over USB 3.0.

    QHYCCD's listed applications include:

    • SWIR astronomy: Imaging and photometry.
    • Daytime star observation: Daytime stars have been captured with the QHY991, and a QHY990 daytime sample was taken with a 1200-1800nm filter.
    • Optical communications and laser work.
    • Scientific research and optical laboratory applications.

    Optical & Mechanical Integration: C-Mount Interface, 17.5mm Back Focus, and 25mm Filter Holder

    The QHY990 has a C-mount front with a 17.5 mm back focus, and 1.25 inch support is available with an adapter. QHYCCD offers SWIR lenses for the QHY990 and QHY991. The body is 92.5 mm long and weighs 520 g.

    QHY990 Series cameras include a 25 mm filter holder; the 25 mm filter is a very common type for lab applications, and the holder supports D=25mm and D=25.4mm filters. A trigger-in socket (RCA type, opto-isolated) is also fitted.

    SWIR Applications: Daytime Astronomy and Industrial Analysis

    QHYCCD's sample images show what the camera records. A QHY990 daytime sample used a 16mm f/1.4 SWIR lens at f/2.8, a 1200-1800nm filter, gain 0 and a 1.3ms exposure. A night-sky sample used the same lens at f/1.4 and filter: 29 stacked 2-second frames at -11°C sensor temperature, dark frame calibrated.

    In astronomy, applications include SWIR imaging, photometry and daytime star observation. An Orion Nebula first light image was taken with the QHY992 and a 1200-1700 nm bandpass filter, showing core details that differ from visible light.

    QHY990 vs. QHY991 & QHY992: Choosing the Right Sensor

    The QHY990 is part of a series of cameras that share the same core technology but use different Sony InGaAs sensors.

    • QHY990 (This Model): Features the IMX990 sensor with a 1296 x 1032 resolution and 5.0 µm pixels. It reaches 66 FPS at full resolution with a typical 112ke- full well.
    • QHY991: Uses the IMX991 sensor, which has the same 5.0 µm pixel size but a lower resolution of 656 x 520. It reaches 123 FPS at full resolution.
    • QHY992: Employs the IMX992 sensor, which offers a much higher resolution of 2592 x 2056 but with smaller 3.45 µm pixels. Its full well is 30ke- (LG AllPixel Mode) and its frame rate 48 FPS at 8-bit.

    Software Ecosystem: QHYCCD All-In-One Pack, ASCOM, and Third-Party Support

    QHYCCD provides a comprehensive software package to control the QHY990. The All-In-One Pack includes system drivers, EZCAP_QT capture software, and ASCOM drivers for broad compatibility with third-party astronomy software. SharpCap is also included in the pack, authorized by SharpCap, and N.I.N.A connects through the QHY plugin or the ASCOM driver.

    To get started, install the All-In-One pack, then connect the camera to its 12V supply (40W at 100% cooler power) and to the computer with a USB 3.0 cable. Use 64-bit software such as SharpCap x64 and N.I.N.A x64. Once installed, software like SharpCap or N.I.N.A. will recognize the camera, giving you full control over exposure, gain, cooling, and capture settings. The ASCOM driver lets ASCOM programs such as MaxIm DL control the camera.

  • What applications does QHYCCD list for the QHY990 SWIR camera?

    The QHY990 is designed for scientific and industrial short-wave infrared (SWIR) applications, including SWIR astronomy imaging and photometry, daytime star observation, optical communications, laser, scientific research and optical laboratory applications.

    Why is powerful cooling so important for the QHY990's InGaAs sensor?

    InGaAs sensors inherently produce a higher dark current than silicon-based sensors, so powerful cooling is necessary; the QHY990's dual-stage TEC cooler reaches 35°C below ambient.

    What is the advantage of the Sony sensor's Cu-Cu interconnect technology in the QHY990?

    The Cu-Cu interconnect technology gives the sensor very low FPN noise and a low defect pixel ratio.

    Can the QHY990 be used for daytime astronomy?

    Yes. Daytime star observation is one of its applications, and a QHY990 daytime sample was taken with a 1200-1800nm filter, gain 0 and a 1.3ms exposure.

    What is the main difference between the QHY990 and QHY991 cameras?

    Both cameras use sensors with 5.0 µm pixels. The primary difference is resolution and speed. The QHY990 has a 1296 x 1032 sensor with a max frame rate of 66 FPS. The QHY991 has a smaller 656 x 520 sensor but offers a much faster max frame rate of 123 FPS,

    What filters can I install in the QHY990's built-in filter holder?

    The QHY990 camera includes an integrated holder for standard 25mm diameter filters. 25 mm is a very common filter type for lab applications, and the holder supports D=25mm and D=25.4mm filters.

    What power supply do I need for the QHY990?

    The QHY990 requires a stable 12V DC power source. The camera consumes up to 40W when the TEC cooler is operating at 100% power. QHYCCD asks for an input voltage between 11V and 13.8V; if it is too low, the camera may stop functioning or reboot when the TEC power percent is high.

    Do I need to use liquid cooling with the QHY990?

    The QHY990 cools by air with a dual-stage TEC to 35°C below ambient. QHYCCD writes that the QHY990 Series supports both air cooling and liquid cooling.

    How do I control the QHY990 with software like N.I.N.A. or SharpCap?

    Install the QHYCCD All-In-One pack, connect the camera to 12V power and USB 3.0, then select it in your software. N.I.N.A connects through the QHY plugin or the ASCOM driver, and SharpCap is included in the pack.

    What does the Electronic Global Shutter on the QHY990 do?

    An electronic global shutter ensures that all 1.3 million pixels on the sensor start and stop collecting light at the exact same time. This avoids the skew a rolling shutter gives on moving subjects.

  • Sensor Sony InGaAs (IMX990/IMX991/IMX992)
    Sensor Technology Cu-Cu Interconnect
    Spectral Range 400 nm to 1700 nm
    Peak Quantum Efficiency 77% at 1200 nm
    Cooling System Regulated air cooling; liquid cooling ready
    Air Cooling Performance ΔT = 35°C below ambient
    Liquid Cooling (Water) ΔT = 45°C below ambient (per series overview)
    Liquid Cooling (Cold Liquid) ΔT = 60°C to 80°C below ambient (per series overview)
    Interface C-Mount
    Back Focus 17.5 mm
    Filter Holder Integrated, for 25 mm filters
    Resolution (W x H) 1296 x 1032
    Pixel size 5.0 µm
    Sensor diagonal 8.28 mm
    ADC 12-bit
    Full well 112,000 e-
    Read noise (min-max) 135 e- (typical, after bias FPN calibration)
    Shutter Electronic Global Shutter
    Buffer memory 128MB DDR2
    Data interface USB 3.0
    Max frame rate at full resolution 66 FPS (8-bit and 16-bit)
    Power requirement 12V, 40W at 100% TEC
    Weight 520 g
    Length 92.5 mm
    Color or Mono Mono
    • QHY990 camera, locking power cable, external trigger cable, USB 3.0 cable (2m), 12V power adapter, AV power cable, guiding cable, desiccant tube, driver download instructions card.

      × 1

  • QHYCCD Warranty