Skip to content

Language

Country

Shelyak Lhires III Spectroscope

by Shelyak
SKU SHK-ES0002
Original price $5,359.00 - Original price $5,359.00
Original price
$5,359.00
$5,359.00 - $5,359.00
Current price $5,359.00
Price Match Policy!
  • Resolving power of R=18,000 with the included 2400 lines/mm grating
  • Selectable wavelength range from 400 nm to 750 nm
  • Optimized for F/10 telescopes like Schmidt-Cassegrains
  • Interchangeable slit with 15, 19, 23, and 35 µm widths included
  • Integrated C-mount guide port with 0.8x focal reducer and 17.5 mm back focus
  • Compact body weighing 1.7 kg
Backordered
Availability Info
FREE Shipping in CONUS
  • Description
  • FAQ
  • Specifications
  • In the Box
  • Downloads
  • Warranty
  • Shelyak Lhires III Spectroscope

    The Shelyak Lhires III Spectroscope delivers a resolving power of R=18,000, enabling detailed analysis of individual spectral lines for astrophysical research. Optimized for F/10 optical systems, it integrates a 2400 lines/mm grating and an interchangeable slit with 15, 19, 23, and 35 µm widths to balance resolution and brightness. Its mirror slit design works with the integrated 0.8x C-mount guide port, which provides 17.5 mm of back focus, so the target star can be positioned and held in the slit, and a micrometer selects any wavelength from 400 to 750 nm.

    The Lhires III: A High-Resolution Tool for Stellar Astrophysics

    The Lhires III is Shelyak's historic instrument, designed at the CNRS Astrophysics School for the observation of Be stars and since used for a wide range of applications. It is the ideal tool for the Doppler effect and for observing star activity, with detail in one or more spectral lines.

    The 200mm Littrow High Resolution Spectrograph (LHIRES) Design

    Lhires is an acronym for Littrow High REsolution Spectrograph. In this configuration, the same 200mm focal length lens (30mm diameter) acts as both the collimator and the imaging lens. Light passing through the slit is collimated, sent to the reflection grating, and the dispersed spectrum is then focused back through the same lens onto the detector. This avoids separate collimating and focusing lenses, which keeps the Lhires III compact and economical to produce. It weighs 1.7 kg.

    R=18,000 Resolving Power Across the 400-750 nm Range

    With its standard 2400 lines/mm grating, the Lhires III achieves a resolving power of R=18,000. This gives access to Doppler velocity measurements and a great deal of detail in the profile of a line. While the high resolution limits the spectral range captured in a single exposure to about 10 nm, a precision micrometer allows you to rotate the grating and center any wavelength between 400 nm and 750 nm on your sensor. You can, for example, centre H-alpha or the sodium D lines.

    The Mirror Slit and 0.8x Focal Reducer Guide Port

    Precise guiding is essential for high-resolution spectroscopy. The Lhires III employs a highly polished, reflective entrance slit that acts as a mirror for the surrounding starfield. This light goes to the guide port, where a guiding camera (not supplied) lets you position the star in the slit and autoguide. The guide port is a dual-lens C-mount port (focal ratio 0.8x) with 17.5 mm mechanical backfocus for the guide camera.

    Optimized for F/10 Schmidt-Cassegrain Systems

    The ideal input focal ratio is F/10, which suits Schmidt-Cassegrain telescopes; the manual gives an acceptable range of f/8 to f/12. Refractors and Newtonians work if they are slower than f/8. For faster telescopes, a Barlow lens can raise the focal ratio, but check that your telescope has enough back focus, particularly a Newtonian.

    SCT Connection and 13mm Back Focus Camera Adapter

    The Lhires III attaches directly to the rear cell of a Schmidt-Cassegrain telescope with the supplied Schmidt-Cassegrain interface. For a 2-inch focuser, use the optional 2-inch adapter. On the detector side, the instrument includes a CCD adapter designed for ATIK cameras, (13 mm mechanical backfocus). Shelyak offers other adapter rings for different cameras in its accessories catalogue, and the manual says there is enough back focus to use a DSLR with its own T-ring.

    Acquisition and Guiding Camera Integration

    The Lhires III uses two cameras. The acquisition camera records the spectrum on the camera port; the guiding camera (not supplied) goes on the C-mount port and watches the star on the mirror slit. The manual notes that most autoguiding software works, and that IRIS includes an algorithm for guiding on a mirror slit.

    Integrated Neon Lamp and Optional Modules

    Accurate wavelength calibration is fundamental to spectroscopy. A neon calibration lamp is integrated in the spectrograph for reference emission lines. The neon lamp is powered with 12V. Shelyak offers optional grating modules for other resolutions, and the Lhires III Plus update kit adds an Argon-Neon lamp and a flat lamp.

    From Raw Frames to Calibrated Spectra

    Acquiring a spectrum is only the first step. The raw 2D images from your camera must be pre-processed (bias, dark, and flat-field correction), corrected for geometric distortions, and calibrated in wavelength. The Lhires III manual points to IRIS and VisualSpec for extracting and calibrating profiles. A large community shares examples and advice on the Spectro-L discussion list and the ARAS forum.

    Measuring Doppler Shifts and Tracking Be Stars

    The Lhires III suits many projects. You can measure the rotation of Jupiter or Saturn by observing the tilt of solar absorption lines across the planet's disk. Other projects include spectroscopic binaries and Be stars, and tracking variable stars. Numerous scientific papers have been based on observations with a Lhires III, in collaboration between amateur and professional astronomers.

    A Compact 1.7 kg, 250mm x 200mm x 83mm Build

    The Lhires III measures 250 mm x 200 mm x 83 mm and weighs 1.7 kg. It comes with the 2400 lines/mm grating module, the interchangeable slit (15, 19, 23, 35 µm), the Schmidt-Cassegrain interface, the CCD adapter for 13 mm back focus cameras and an eyepiece holder for observing the Sun's spectrum by eye (eyepiece not supplied). The manual suggests a first session in daylight: point the slit at the sky, look at the solar spectrum and explore it with the micrometer.

  • What kind of telescope works best with the Shelyak Lhires III?

    The ideal input is F/10, which suits Schmidt-Cassegrain telescopes; the manual gives f/8 to f/12 as acceptable. Refractors and Newtonians slower than f/8 can be used, and faster telescopes can use a Barlow lens if the back focus allows.

    Can I use the Lhires III Spectroscope to measure the rotation of Jupiter?

    Yes. The rotation of Jupiter or Saturn is an educational Doppler project. By orienting the slit along Jupiter's equator, you capture the spectrum from both the approaching (blue-shifted) and receding (red-shifted) limbs of the planet. This causes the solar absorption lines reflected from the planet's atmosphere to appear tilted, and the degree of tilt is a direct measurement of the rotational velocity.

    What do I need to start autoguiding with the Lhires III?

    You need a C-mount guide camera (not supplied) and autoguiding software. The guide port is a dual-lens C-mount port (0.8x) with 17.5 mm back focus, and the mirror slit sends the field around the slit to it, so the star can be held in the slit.

    How do I attach my imaging camera to the Lhires III?

    The Lhires III includes a standard adapter for ATIK cameras, which have a 13 mm mechanical back focus. For other cameras, Shelyak offers adapter sets for 17, 23, 25 and 34 mm back focus in its accessories catalogue.

    Is the Lhires III a good tool for studying Be stars like Gamma Cassiopeiae?

    Yes. The Lhires III was designed for the observation of Be stars, and the manual shows a 2D spectrum of Gamma Cas. At R=18,000 you see the shape of the H-alpha emission profile and can follow its changes, a common amateur-professional collaboration topic.

    How do I select a specific wavelength to observe with the Lhires III?

    The Lhires III uses a manual micrometer screw to precisely rotate the internal grating. Turning the micrometer changes which part of the spectrum falls onto your camera sensor. This allows you to center any wavelength in the visible range (400 nm to 750 nm), giving you the flexibility to study any specific spectral feature of interest.

    What is the purpose of the different slit widths (15, 19, 23, 35 µm)?

    The slit width presents a fundamental trade-off between resolution and light throughput.

    • Narrower slits (15 µm, 19 µm): Provide the highest spectral resolution but allow less light to pass through. Use them when detail matters most.
    • Wider slits (23 µm, 35 µm): Allow more light to reach the sensor, improving the signal-to-noise ratio for fainter targets, at the cost of resolution.

    The slit lets you give priority to resolution or brightness.

    Can I use a DSLR camera with the Lhires III?

    Yes. The manual says the camera side is an M42 T-ring thread with enough back focus for a DSLR; the brand-specific T-ring is not supplied.

    What is the difference between the standard 2400 l/mm grating and optional lower-resolution gratings?

    The standard 2400 lines/mm grating provides the maximum resolving power of R=18,000. Optional grating modules (such as 1800, 1200, 600, 300 and 150 l/mm) lower the resolving power and make fainter objects accessible; examples are novae and bright comets. With a 200 mm f/10 telescope (1 hour, S/N 100), limiting magnitudes range from 5.0 with the 2400 grating to 9.2 with the 150 grating.

    How do I calibrate my spectra taken with the Lhires III?

    Calibration involves several steps. First, you must take calibration frames (bias, darks, flats). For wavelength calibration, you use the integrated Neon lamp to take a reference spectrum. Software such as IRIS or VisualSpec then uses the known wavelengths of the Neon emission lines to create a dispersion solution, which converts the pixel positions in your star's spectrum into an accurate wavelength scale in angstroms or nanometers.

    What does the Littrow design mean for the Lhires III?

    In a Littrow spectrograph, the same lens collimates the light onto the grating and focuses the spectrum onto the camera. This removes the separate lenses of Czerny-Turner or Ebert designs, so the Lhires III is compact and economical to produce.

  • Guide Port Specifications Dual-lens C-mount with 0.8x focal reducer
    Guide Camera Back Focus 17.5 mm
    Weight 1.7 kg
    Dimensions 250 mm x 200 mm x 83 mm
    Detector Compatibility Accepts adaptor rings for CCD, CMOS, and DSLR cameras
    Wavelength range 400-750 nm (selectable, about 10 nm per setting)
    Telescope-side connection SCT interface (2-inch SCT thread), optional 2-inch adapter
    Camera-side connection CCD adapter for ATIK cameras (13 mm back focus)
    Resolving power R = 18,000 (2400 lines/mm grating module, supplied)
    Aperture F/10
    Supplied slit interchangeable 15, 19, 23, 35 µm
    • Lhires III spectroscope with 2400 lines/mm grating module

      × 1

    • Interchangeable slit (15, 19, 23, 35 µm)

      × 1

    • Schmidt-Cassegrain telescope interface

      × 1

    • CCD adapter (camera with 13 mm back focus)

      × 1

    • Eyepiece holder (eyepiece not supplied)

      × 1

  • Shelyak 1-Year Warranty