Shelyak Grating module for the UVEX - 150 l/mm
- 150 lines/mm Grating Density
- Designed for the Shelyak UVEX Spectroscope
- Optimized for Low-Resolution, Wide-Coverage Spectroscopy
- Interchangeable Module for UVEX System
This optional 150 lines/mm grating module expands the capabilities of your UVEX spectroscope, sitting at the lowest-resolution end of a lineup that includes 300, 600, 1200, and 1800 l/mm options. By trading the high resolution of the standard 600 l/mm grating for maximum wavelength coverage, the 150 l/mm module is purpose-built for survey work and classifying a wide range of celestial objects in a single exposure.
The primary role of the 150 l/mm grating is to capture the widest possible spectral range that your camera sensor can accommodate in a single frame. This low-dispersion capability is essential for survey projects where the goal is to quickly characterize many targets, such as classifying stars, identifying supernova types, or monitoring cometary emissions.
For faint targets, lower dispersion concentrates the object's light over fewer pixels, increasing the signal-to-noise ratio of the continuum. This makes the 150 l/mm grating the most efficient choice for obtaining usable spectra of faint novae, asteroids, or distant quasars where capturing the overall spectral shape is more critical than resolving fine details.
Choosing between the optional 150 l/mm grating and the standard 600 l/mm grating is a direct trade-off between spectral detail and wavelength coverage. Your scientific objective determines which is the correct tool for the job.
You should choose the 150 l/mm grating when your primary goal is to capture the widest possible range of wavelengths in a single exposure. It is ideal for survey work, classifying unknown objects, or studying targets with very broad spectral features. The standard 600 l/mm grating is better when you need high resolution to study fine details within a narrow spectral window.
The UVEX 150 l/mm grating is excellent for both. Type Ia supernovae are identified by a characteristic broad silicon absorption feature (Si II) at 6150Å, which is easily captured with this grating's wide coverage. Wolf-Rayet stars have extremely broad emission lines (sometimes hundreds of angstroms wide) from stellar winds, and the 150 l/mm grating ensures the entire profile of these features fits within a single frame.
Yes. Because the 150 l/mm grating disperses light less than a higher-density grating, it concentrates the starlight onto fewer pixels on your camera sensor. This results in a higher signal-to-noise ratio for the stellar continuum in a given exposure time, making it more efficient for capturing spectra of faint objects.
No, this is not the right tool for that task. The low resolution of the 150 l/mm grating is insufficient for measuring the small Doppler shifts required for precise radial velocity work. For those applications, a higher resolution grating, such as the standard 600 l/mm or the optional 1200 l/mm, is necessary.
The 150 l/mm grating is the better choice for initial comet classification. Cometary spectra often show broad emission bands from molecules like C2 (the Swan bands) and CN spread across the visible spectrum. The wide coverage of the 150 l/mm grating allows you to capture all these features simultaneously to quickly assess the comet's composition.
No, the Shelyak UVEX is designed as a modular system. Swapping gratings is a straightforward process, allowing you to reconfigure the spectroscope in the field to match your observing target and scientific goals for the night. Always refer to the UVEX manual for the correct procedure.
| Grating Density | 150 lines/mm |
| Compatibility | Shelyak UVEX Spectroscope |
UVEX 150 l/mm Grating Module
× 1