Skip to content

Language

Country

Shelyak LISA Spectroscope (VIS)

by Shelyak
SKU SHK-PF0021V
Original price CA$7,432.00 - Original price CA$7,432.00
Original price
CA$7,432.00
CA$7,432.00 - CA$7,432.00
Current price CA$7,432.00
Price Match Policy!
  • Designed for faint object spectroscopy at low resolution
  • Resolving power of R~1,000 with the included 23 µm slit
  • Optimized for f/5 optical systems
  • Covers the visible spectrum from 400 nm to 700 nm
  • Mirror slit design with C-mount port for precise autoguiding
  • Includes four interchangeable slits: 15, 19, 23, and 35 µm
  • 1.4 kg without camera
Backordered
Availability Info
FREE Shipping in Canada
  • Description
  • FAQ
  • Specifications
  • In the Box
  • Downloads
  • Warranty
  • Shelyak LISA Spectroscope (VIS)

    The Shelyak LISA Spectroscope is a high-luminosity instrument dedicated to the spectroscopy of faint objects, weighing just 1.4 kg without a camera. Its fast f/5 optical system delivers a resolving power of approximately 1,000 using the 23 µm slit, covering a spectral range from 400 nm to 700 nm. The design incorporates a 4 mm long mirrored slit for precise guiding and is supplied with an interchangeable slit (15, 19, 23 and 35 µm) to favour resolution or brightness as needed.

    The Shelyak LISA (VIS): A Spectroscope for f/5 Systems

    The LISA is engineered specifically for capturing spectra of faint and diffuse deep-sky objects where high light-gathering power is more critical than ultra-high resolution. It is the most sensitive instrument in Shelyak's range, dedicated to comets, novae, supernovae, faint variable stars, the redshift of distant galaxies or quasars and the confirmation of planetary nebulae.

    An f/5 Design with a 0.68x Internal Reduction

    The optical path of the LISA begins with light from an f/5 telescope beam passing through the slit. A collimator with a 130mm focal length transforms this light into a parallel beam before it strikes the diffraction grating. After dispersion, an 88mm objective lens focuses the spectrum onto the camera sensor. The slit image is therefore multiplied by 88/130 = 0.68 on the sensor. Shelyak credits this internal reducer and the low resolution for the LISA's sensitivity on faint objects.

    R~1,000 Resolving Power from 400 nm to 700 nm

    With the 23 µm slit, the LISA reaches a resolving power (R) of about 1,000; R ranges from about 600 to 1,000 depending on slit and mode. The VIS (Visible) configuration covers 400 nm to 700 nm, and the range even extends into the near UV and near IR.

    A 4 mm Mirrored Slit with Four Interchangeable Widths

    The LISA's slit assembly is central to its functionality. The slit is a mirror slit: the field around it is sent to the guiding camera port, so you can position the target accurately on the 4 mm long slit and hold it there.

    • Included Slits: The standard interchangeable slit carries 15, 19, 23 and 35 µm widths, so you can favour resolution or brightness.
    • Autoguiding Port: The reflected field of view is directed to a C-mount port with a 17.5 mm backfocus, where a guiding camera (not supplied) lets you autoguide the telescope.
    • Optional Slits: For specialized applications, Shelyak offers optional wide slits and photometric slits.

    Matching the LISA to Your Telescope's Focal Ratio

    To achieve maximum throughput, the LISA is designed to be fed by an f/5 light cone. You can install it on telescopes that are natively f/5. On Schmidt-Cassegrain or Ritchey-Chrétien telescopes, generally f/10 or f/8, use a focal reducer to bring the focal ratio close to f/5. A Schmidt-Cassegrain takes an f/6.3 reducer and an SCT T-adapter, with a longer spacing between the LISA and the reducer to reach f/5.

    M42, C-Mount, and 2" Nosepiece Connections

    The LISA provides standardized mechanical interfaces for easy integration into your existing setup.

    • Telescope Connection: The instrument includes a 2" nosepiece for use in standard 2" focusers. The nosepiece can be removed to reach a female T-mount thread (M42x0.75mm). For a Schmidt-Cassegrain (2" external thread) you need the optional BA0027 variable T-adapter.
    • Imaging Camera Connection: The acquisition camera attaches via a male M42x0.75 T-thread. The backfocus is 54.9 mm; the manual says the T-mount thread can also take a DSLR with a T-ring.
    • Guiding Camera Connection: The autoguider port uses a standard C-mount interface with a 17.5 mm backfocus.

    Sensor Matching for Acquisition and Guiding

    The acquisition camera mounts on the T-mount thread at 54.9 mm backfocus, and the guiding camera (not supplied) on the C-mount port at 17.5 mm. The manual adds that all Lhires III camera adapters fit the LISA, since both instruments have the same spectrum port backfocus.

    The LISA includes two adapter rings to help achieve correct spacing for cameras with different backfocus requirements. For ATIK cameras you need the 13mm ring (13mm mechanical backfocus), supplied with the LISA; the second adapter is for cameras with 17mm backfocus.

    Integrated Features for High-Precision Wavelength Calibration

    Accurate scientific results depend on precise wavelength calibration and flat-fielding. Light can be injected through a calibration window (tungsten lamp, neon lamp, energy saver lamp), and a white screen controlled by an electro-magnet can be moved to send this light to the slit; when it is in front of the slit, it stops starlight entering the spectrograph. The optional calibration module adds an Argon/Neon lamp, with many emission lines over the whole LISA range, and a tungsten lamp for flats.

    From Acquisition to Final Spectrum with Demetra

    Shelyak provides the free Demetra software, and the LISA manual also names IRIS, AudeLA, RSpec and VisualSpec. The process includes standard steps like bias and dark subtraction, flat-fielding to correct for instrumental response, and geometric correction of the 2D spectrum. Then come sky background subtraction, extraction of the 1D profile (the manual describes optimal extraction) and wavelength calibration with your reference lamp spectrum. The final step is to apply an instrumental response correction, typically derived from observing a reference star of a known spectral type, to produce a scientifically valid spectrum.

    Contributing to Novae, Supernovae, and Comet Research

    The LISA is a tool for collaboration between amateur and professional astronomers: novae, supernovae, comets, symbiotic stars and the confirmation of planetary nebulae. Many scientific publications are based on LISA observations, with examples such as an ATEL on H-alpha in SS433 and spectroscopy of classical novae. Advice and examples are shared on the spectro-L discussion list and the ARAS forum.

    A 1.4 kg Instrument Ready for the Field

    The LISA weighs 1.4 kg without a camera; the manual reminds you to check the total weight capacity of your mount. Focusing can be started during the day with an energy-saver lamp or a neon lamp, as the manual describes.

  • What kind of objects is the Shelyak LISA Spectroscope designed for?

    Shelyak dedicates the LISA to faint objects. These include novae, supernovae, comets, faint variable stars, planetary nebulae, distant galaxies, and quasars.

    What telescope do I need to use the Shelyak LISA?

    The LISA is an f/5 instrument. It can be installed on telescopes that are natively f/5, or on f/10 or f/8 Schmidt-Cassegrain and Ritchey-Chrétien telescopes with a focal reducer that brings the focal ratio close to f/5.

    How do I keep a star centered on the Shelyak LISA's slit for long exposures?

    Its mirror slit reflects the starfield around the slit to a guiding camera, so you can see the target for initial positioning. The guiding camera (not supplied) attaches to the C-mount guide port (17.5 mm backfocus) and lets you autoguide the telescope.

    Can I change the spectral resolution of the Shelyak LISA?

    Yes. The resolution depends on the slit width. It includes an interchangeable slit holder with four slits: 15, 19, 23, and 35 µm. Using a narrower slit (like 15 µm) provides higher resolution for separating fine spectral details on brighter targets. Using a wider slit (like 35 µm) allows more light in, increasing sensitivity for very faint objects at the cost of lower resolution.

    How would I use the Shelyak LISA on a faint supernova in a galaxy?

    For a faint, distant target like a supernova, you would prioritize light gathering. You would select one of the wider slits, likely the 23 µm or 35 µm, to maximize throughput. With the guiding camera on the mirror slit you find the supernova in its galaxy, place it on the slit and autoguide to hold it there during the exposures.

    Can I use the Shelyak LISA with my 8" f/10 SCT?

    Yes, but you will need a focal reducer to achieve optimal results. An f/10 beam is too slow for the LISA's f/5 design. The manual suggests an f/6.3 reducer with an SCT T-adapter, spaced further from the LISA to reach f/5. To mount on the SCT's 2" external thread you need the optional BA0027 variable T-adapter.

    What does the ~1,000 resolving power of the Shelyak LISA let me do?

    With R~1,000 across 400 to 700 nm, you record the whole visible spectrum of faint targets in one shot: the Balmer lines of stars, the main emission lines of nebulae (such as H-alpha, H-beta and [O III]) and the broad lines of novae and supernovae.

    What is the purpose of the internal calibration screen on the Shelyak LISA?

    The internal screen allows you to take calibration frames (flats with a tungsten lamp, and wavelength references with a Neon/Argon lamp) without removing the spectroscope from the telescope. An electro-magnet moves a white screen in front of the slit; it stops starlight and sends the calibration light into the spectrograph. The calibration connector is 12V (2.5mm, positive in the center).

    What cameras are recommended for the Shelyak LISA?

    No specific camera is named for the LISA. The imaging port is a T-mount thread with 54.9 mm backfocus; the guide port is C-mount with 17.5 mm backfocus. The LISA includes 13 mm and 17 mm adapters to accommodate cameras with different backfocus needs (the 13 mm ring is for ATIK cameras).

    How do I process the data from the Shelyak LISA?

    Shelyak provides Demetra, and the LISA manual names IRIS, AudeLA, RSpec and VisualSpec. The general process involves:

    1. Pre-processing: Calibrating raw images with bias, dark, and flat frames.
    2. Geometric Correction: Correcting for any rotation or tilt in the 2D spectrum.
    3. Extraction: Subtracting the sky background and extracting the 1D spectral profile from the 2D image.
    4. Calibration: Applying a wavelength solution using a spectrum from a known reference lamp (e.g., Neon).
    5. Instrumental Response Correction: Using a reference star to correct the instrumental response.

    Is the Shelyak LISA difficult to set up for a first-time user?

    While spectroscopy involves more steps than standard imaging, the manual walks through the tuning. Focusing can start in daylight with an energy-saver lamp or a neon calibration lamp.

  • Slit Length 4 mm
    Weight 1.4 kg (without camera)
    Resolving Power ~1,000 (with 23 µm slit)
    Spectral Range 400 - 700 nm (extends to near-UV/IR)
    Aperture f/5
    Included Slits 15, 19, 23, 35 µm
    Telescope Connection 2" Nosepiece or M42x0.75 T-thread (female)
    Imaging Camera Connection M42x0.75 T-thread (male)
    Imaging Camera Backfocus 54.9 mm
    Guiding Camera Connection C-mount
    Guiding Camera Backfocus 17.5 mm
    Camera-Side Connection M42x0.75 (T2) male
    • LISA Spectroscope

      × 1

    • Interchangeable Slit Holder with 4 Slits (15, 19, 23, 35µm)

      × 1

    • 2" Telescope Nosepiece

      × 1

    • Adapters for 13mm and 17mm back focus cameras

      × 2

  • Shelyak 1-Year Warranty